▸Description
Professional Coating Thickness Gauge
The TIME2606 Coating Thickness Gauge is a professional coating thickness gauge designed for high-accuracy, non-destructive coating thickness measurement across a wide range of industrial applications. Supporting both magnetic induction (F) and eddy current (N) measurement technologies, the TIME2606 accurately measures non-magnetic coatings on ferrous substrates as well as non-conductive coatings on non-ferrous metals. With interchangeable probes, advanced statistical analysis, integrated thermal printing, and large-capacity data storage, the TIME2606 is an ideal solution for automotive refinishing, galvanising, powder coating, anodising, electroplating, corrosion protection, manufacturing, and industrial quality control.
The TIME2606 Coating Thickness Gauge supports multiple probe options to suit different measuring ranges and applications, including standard coatings, thick protective coatings, and heavy-duty industrial linings. Furthermore, the instrument provides two working modes (DIRECT and BATCH) together with both SINGLE and CONTINUOUS measurement modes, allowing users to perform rapid spot checks or high-volume production inspections with maximum efficiency. Basic calibration functions enable quick correction of system errors, ensuring reliable and repeatable measurement accuracy across different substrates and coating types.
Designed for Professional Industrial Inspection
The large colour display provides clear measurement results together with comprehensive statistical analysis, including average, maximum, minimum, standard deviation, and total measurement count. In addition, programmable upper and lower tolerance limits with audible alarms allow operators to perform fast PASS/FAIL inspections during manufacturing and quality assurance.
The TIME2606 Coating Thickness Gauge stores up to 10,000 coating thickness measurements, making it suitable for large inspection projects and long-term quality documentation. Moreover, the integrated thermal printer enables immediate printing of measurement results and statistical reports directly from the instrument, eliminating the need for additional equipment. Powered by a rechargeable 3.7 V lithium battery, the TIME2606 combines portability, advanced functionality, and reliable performance for demanding industrial inspection applications.
Key Features
- Professional coating thickness gauge with magnetic induction and eddy current technology
- Measures coatings on both ferrous and non-ferrous substrates
- Interchangeable probe options for different measuring ranges and applications
- DIRECT and BATCH working modes
- SINGLE and CONTINUOUS measurement modes
- Statistical analysis including average, maximum, minimum, standard deviation, and measurement count
- Stores up to 10,000 coating thickness measurements
- Basic calibration for improved measurement accuracy
- Programmable upper and lower tolerance limits with audible alarm
- Integrated thermal printer for instant measurement and statistical reports
- Rechargeable lithium battery for extended field operation
- Ideal for automotive, galvanising, powder coating, anodising, electroplating, corrosion protection, manufacturing, and quality control
| General Information | |
| Category | Coating Thickness Gauge |
| Model | TIME2606 |
| Manufacturer (OEM) | Beijing High Time Technology Co., Ltd. |
| Features | ▪ Dual operating principles: magnetic induction (ferrous) and eddy current (non-ferrous) for non-destructive measurements ▪ Two working modes: DIRECT and BATCH; two measuring modes: CONTINUOUS and SINGLE ▪ Statistical functions include mean, maximum, minimum, number of tests, and standard deviation ▪ Memory capacity of up to 10,000 data points ▪ System error can be corrected using basic calibration methods ▪ Alarm function with preset upper and lower limits ▪ Low battery indicator ▪ Integrated thermal printer for printing measurement and statistical values ▪ Error warning displayed in case of malfunction ▪ Manual or automatic power-off function |
| Technical Specification | |||||||
| Parameter | F1.5 | N1.5 | FN1.5 | F1.5R | F3.5 | FN3.5 | F10 |
| Working Principle | Magnetic induction | Eddy current | Both | Magnetic induction | Magnetic induction | Both | Magnetic induction |
| Measuring Range | 0–1500 µm | 0–3500 µm | F: 0–3500 µm; N: 0–3000 µm | 0–10000 µm | |||
| Minimum Resolution | 0.1 µm | 1 µm | |||||
| Tolerance | ± (1% H + 1) µm | ± (1% H + 3) µm | ± (1% H + 5) µm | ||||
| Min. Curvature Radius | Convex 1.5 mm | Convex 5 mm | Convex 10 mm | ||||
| Min. Area Diameter | Ø7 mm | Ø10 mm | Ø40 mm | ||||
| Critical Substrate Thickness | 0.5 mm | 0.3 mm | F: 0.5 mm; N: 0.3 mm | 0.5 mm | 0.5 mm | 2 mm | |
| Operating Temperature (°C) | 10–30 | ||||||
| Humidity | ≤ 75% RH | ||||||
| Working Environment | No strong magnetic field | ||||||
| Power Supply | Li battery 3.7 V, 2200 mAh | ||||||
| Dimensions (mm) | 203.4 × 92.1 × 52.1 | ||||||
| Weight (g) | 400 | ||||||
| Standard Delivery | |
| Main Unit | 1 |
| Probe (FN1.5) | 1 |
| Substrate | 1 |
| Calibration Foil | 1 |
| Charger | 1 |
| TIME Certificate | 1 |
| Warranty Card | 1 |
| Instruction Manual | 1 |